logo

Emerson Rosemount in Situ Oxygen Analyzer CX1100 CX2100 Flue Gas Oxygen Measurement Solution

1
MOQ
2250~2500$
цена
Emerson Rosemount in Situ Oxygen Analyzer CX1100 CX2100 Flue Gas Oxygen Measurement Solution
Характеристики Галерея Характер продукции Спросите цитату
Характеристики
Характеристики
Протокол связи: 4-20 ХАРТ
Отростчатый диапазон температур: До 1300 °F (705 °C) или 1922 °F (1050 °C)
Диапазон температуры окружающей среды: От 40 до +149 °F (от -40 до +65 °C)
Тип измерения: Кислород, цирконий - паяный диск
Размеры: Варианты длины зонда от 18 дюймов до 6 футов
Диапазон измерений: от 0 до 10% или от 0 до 50%
Основная информация
Фирменное наименование: Rosemount
Номер модели: CX2100
Оплата и доставка Условия
Условия оплаты: T/T, L/C.
Характер продукции

Product Overview

The Rosemount CX Series In-Situ Oxygen Analyzers are designed to provide continuous, accurate oxygen measurement in combustion processes. Engineered by Emerson, these analyzers—CX1100 and CX2100—help industries achieve optimal combustion control, reduce fuel consumption, and minimize emissions.
With advanced sensor technology, durable probe design, and smart diagnostics, the CX Series ensures reliable operation even in harsh flue gas environments.


Key Features

  • Real-Time In-Situ Measurement – Continuous monitoring without gas sampling or conditioning.

  • Wide Temperature Compatibility – Suitable for high-temperature furnace and boiler environments.

  • Fast Response & High Accuracy – Enables immediate control feedback for combustion efficiency.

  • Low Maintenance Design – Robust sensor and probe reduce calibration and downtime.

  • Advanced Diagnostics – Smart self-check functions for predictive maintenance.

  • Easy Integration – Seamlessly connects to Emerson process control systems or DCS platforms.


Technical Specifications

Parameter Rosemount CX1100 Rosemount CX2100
Measurement Range 0–25% O₂ 0–25% O₂
Accuracy ±0.75% of reading ±0.75% of reading
Probe Lengths 400–1500 mm 400–1500 mm
Operating Temp Up to 700°C Up to 700°C
Output 4–20 mA / HART 4–20 mA / HART
Power Supply 24 VDC or 110/220 VAC 24 VDC or 110/220 VAC
Mounting Flange or insertion type Flange or insertion type

Applications

  • Power plant boilers and furnaces for combustion optimization

  • Cement kilns and rotary dryers

  • Petrochemical and refining process heaters

  • Steel and glass furnaces

  • Waste incinerators and environmental monitoring systems


FAQ

Q1: What is the main difference between CX1100 and CX2100?
A1: CX1100 is the base model for standard combustion monitoring, while CX2100 includes enhanced diagnostics and a more durable probe for demanding applications.

Q2: How often does the CX Series require calibration?
A2: Typically once every 6–12 months depending on process conditions, thanks to Emerson’s long-life zirconia sensor.

Q3: Can these analyzers be connected to existing DCS or PLC systems?
A3: Yes, they provide standard 4–20 mA and HART output for easy integration.

Q4: What industries commonly use Rosemount CX analyzers?
A4: Power generation, petrochemical, cement, metallurgy, and paper manufacturing industries.


Contact Us

Xiangjing (Shanghai) Mechanical and Electrical Tech Co., Ltd
Address: Building 6, No.98, Fulian 1st Road, Baoshan District, Shanghai, China
Tel: +86-15000725058
Email: edward.zhao@gongboshi.com
Website: www.shgongboshi.com


Related Products

  • Rosemount 5408 Non-Contacting Radar Level Transmitter

  • Rosemount 3301 Guided Wave Radar Level Transmitter

  • Rosemount 3051 Pressure Transmitter

  • Masoneilan Control Valve Series


Tags:

Rosemount Oxygen Analyzer, Emerson CX1100, CX2100, Flue Gas Analyzer, In-Situ O₂ Sensor, Combustion Optimization, Industrial Analyzer, Rosemount Process Automation

Порекомендованные продукты
Свяжись с нами
Контактное лицо : Mr. Edward Zhao
Телефон : +8615000725058
Осталось символов(20/3000)